12V Wire Size Calculator

Size DC wire for RV, van, boat, trailer and solar circuits. Enter amps or watts and the one-way length to get the right AWG and fuse size.

Quick examples

Example values are shown. Change any field to calculate your own circuit.

Jump to result

Enter your circuit

All fields are required unless marked optional.

Load 10 A

Use the amps on the nameplate or breaker. Choose Watts above to enter power instead.

Run 15 ft one-way

Enter the distance from the source to the load, not the round trip.

Circuit DC · 12 V · Copper · 3% max drop

Nominal supply voltage: 120 or 240 V for AC homes, 12 V for most vehicles.

3% is a common design target; use 1–2% for sensitive electronics.

Hotter wire has more resistance. 75 °C is the conservative NEC reference.

Advanced settings

Result

Based on NEC Table 310.16 ampacities and Chapter 9 Table 8 resistance. No temperature or bundling derating. Check with a licensed electrician. How this is calculated

On this page

Why 12 V wiring needs thicker wire

At 12 V, a 3% drop is only 0.36 V. The same current that is trivial on a 240 V circuit therefore needs much heavier wire, and short extra lengths matter. Doubling the run length doubles the voltage drop, and doubling the current does the same.

This calculator is set up for low-voltage DC work: RVs and campervans, boats, trailers, off-grid cabins and solar. It defaults to 12 V, a 3% drop target and room-temperature wire, and it accepts watts or amps.

How to use it

  1. Pick a preset such as fridge, water pump or solar panel to controller, or type your own amps or watts.
  2. Enter the one-way length between the battery or source and the device. The return conductor is included automatically.
  3. Choose your drop target. Use 1–2% for charging circuits and sensitive electronics; 3% for most other loads.
  4. Read the recommended AWG, the voltage at the load, and the suggested fuse size.

Maximum one-way length by wire size at 12 V

This table is generated by the same calculation engine. It shows the longest one-way run, in feet, that stays at or below a 3% drop (0.36 V) with copper wire at 20 °C.

Longest one-way run at 12 V, copper, 3% drop, 20 °C
Wire size 5 A10 A20 A30 A50 A
14 AWG 14.0 ft [4.3 m] 7.0 ft [2.1 m] 3.5 ft [1.1 m] 2.3 ft [0.7 m] 1.4 ft [0.4 m]
12 AWG 22.2 ft [6.8 m] 11.1 ft [3.4 m] 5.6 ft [1.7 m] 3.7 ft [1.1 m] 2.2 ft [0.7 m]
10 AWG 35.3 ft [10.8 m] 17.7 ft [5.4 m] 8.8 ft [2.7 m] 5.9 ft [1.8 m] 3.5 ft [1.1 m]
8 AWG 56.2 ft [17.1 m] 28.1 ft [8.6 m] 14.0 ft [4.3 m] 9.4 ft [2.9 m] 5.6 ft [1.7 m]
6 AWG 89.3 ft [27.2 m] 44.7 ft [13.6 m] 22.3 ft [6.8 m] 14.9 ft [4.5 m] 8.9 ft [2.7 m]
4 AWG 142.1 ft [43.3 m] 71.0 ft [21.6 m] 35.5 ft [10.8 m] 23.7 ft [7.2 m] 14.2 ft [4.3 m]
2 AWG 225.9 ft [68.8 m] 112.9 ft [34.4 m] 56.5 ft [17.2 m] 37.6 ft [11.5 m] 22.6 ft [6.9 m]
1/0 AWG 359.2 ft [109.5 m] 179.6 ft [54.7 m] 89.8 ft [27.4 m] 59.9 ft [18.2 m] 35.9 ft [10.9 m]
2/0 AWG 452.9 ft [138.0 m] 226.4 ft [69.0 m] 113.2 ft [34.5 m] 75.5 ft [23.0 m] 45.3 ft [13.8 m]
4/0 AWG 720.1 ft [219.5 m] 360.1 ft [109.7 m] 180.0 ft [54.9 m] 120.0 ft [36.6 m] 72.0 ft [21.9 m]

Fuse and safety notes

Assumptions and limits

  • Copper or aluminum, stranded, resistance corrected to the chosen wire temperature. Switch to the hot 75 °C setting for conductors in warm engine bays or tightly bundled runs.
  • No derating for bundling or high ambient temperature is applied automatically.
  • Not a substitute for a qualified installer. See the disclaimer.